E N G L I S H
4.2 CURSOR
While the cursor will be fitted the correct way round when the tool is supplied, we recommend that you check its orientation
before fitting the nose equipment. The sprung loaded, slightly concave, end of the cursor should point towards the front of
the tool as shown in the illustration.
When fitted the correct way round, the cursor will easily slide out of the barrel when a mandrel is pushed into its centre then
pulled back.
To reverse the orientation of the cursor, follow these steps:
Item numbers in bold refer to the general assembly and parts list for
the 07530-02200 MkII type on pages 20-21. For the 07532-02200
MkII type, the procedure is the same but the part numbers must be
taken from the general assembly and parts list on pages 22-23.
Remove the clip 47 and slide off end cap 38.
•
Using an Allen Key, remove one cap head screw 44 ensuring
•
that any trapped air is exhausted. remove the second cap head
screw 44.
Pull out rear plug 46.
•
Pull out tail jaw piston assembly 14 together with jaws 9.
•
Lift out spring 13 and jaw housing 8.
•
Insert a mandrel into the hole in the rear end of barrel 25 until it protrudes through the front of the barrel, then pull out
•
the mandrel and cursor together through the front.
•
Reassemble components in reverse order.
•
Insert Mechanical Cursor Assembly 5 into the front of the barrel, correct way round.
4.3 LOADING AND RELOADING THE TOOL
The procedure for loading the tool and for fitting the nose equipment to the tool is integral.
When ordering a complete tool or system you will normally be supplied with all the nose equipment required for the
fastener to be placed.
To identify nose equipment components or to select the correct elements, read the nose equipment section, in the
accessories manual (07900-09508).
If you have been supplied with a nose jaw, mandrels and mandrel follower springs proceed with loading the tool and fitting
the nose equipment as shown overleaf.
Item numbers in bold refer to the general assembly and parts list for the 07530-02200 MkII type on pages 20-21. For the
07532-02200 MkII type, the procedure is the same but the part numbers must be taken from the general assembly and parts
list on pages 22-23.
12
If fitted incorrectly, the cursor will not allow feeding of the fasteners.
IMPORTANT
IMPORTANT
O R I G I N A L I N S T R U C T I O N
CURSOR
SPRING
LOADED END
NOSE
JAWS
TOOL
BARREL