Troubleshooting

11. Troubleshooting
Symptom
Battery icon is displayed
Display blank
Meter does not latch for
batching
Slow or no fluid flow
Meter inaccurate
Batch overruns program value
Relieve the pressure prior to
checking or repairing the meter.
Make sure all valves, controls and
pumps are operating correctly.
Possible cause
Batteries are low
Meter asleep
Loose battery connection
Batteries dead
Meter not in AUTO mode
Meter not reset after prior batch
Low batteries
Filter is clogged
Pump pressure is low
Foreign material is jamming meter
Scale factor not correct for fluid
Pulse delay value set too low
LM_OGP2Adv_BA_89_1008
page 41/92
Remedy
Replace batteries
Push reset button
Remove battery pack
and check battery
connection / Push reset
button
Replace batteries / Push
reset button
Press AUTO button and
program batch size
Press RESET button
Check for battery icon/
replace batteries/push
RESET button
Clean or replace the filter in
the swivel nut
Turn up the pump pressure
Contact your local repair
distributor
Enter program mode,
check and reset program
factor
Enter program mode, reset
pulse delay to higher value