ADJUSTING DOOR PANEL
• In this step, you'll need following part: [27]
• In this step, you'll need the following tool: H
5a. Close Door Panel [9] and observe if there are any gaps between the Door Panel [9] and Fixed Panel B [11]
or if the door is high or low at any location (ref. illustration). Also both Fixed Door Panels A or B can be
moved in or out from the Wall Post [1] (note: will need to loosen Adjustment Fixtures [15] to do so to aid
in adjusting the Door Panel [9]).
5b. If Door Panel [9] is lower when closed against Fixed Panel B [11], then slide Gasket [27] under Fixed
Panel A [10] to slightly raise Door Panel [9].
5c. Trim Gasket [27] with Utility Knife [H].
5d. Further adjustment of any gap between Door Panel [9] and Fixed Panel B [11] can be made my pushing
either Magnetic Seal [7] or [8] in or out.
5e. Once all adjustments have been made, verify that the Door Panel [9] closes smoothly and correctly with
no gaps. (ref. illustration).