Storage
The water purifier should be put into storage if it:
•
is going to be disconnected from water and electricity for an extended period (several days)
•
is not going to be used to produce purified water for a period of longer than 4 months.
Dosage:
•
2 litres preserving agent + 4 litres water provides protection against freezing down to –15 °C.
•
3 litres preserving agent + 3 litres water provides protection against freezing down to –30 °C.
Preserving agents can be ordered from your dealer (see "Consumables").
This product must be kept out of the reach of
children. Wash your hands after use!
1. Pull out the plug.
2. Mix preserving agent and water in a bucket, see
fig. E. Dosage, see above.
3. Unscrew both filter containers according to the
section "Replacing the filters". Remove the two
filters and discard them (do not save), empty the
containers of water.
4. Reinstall the empty filter containers. Ensure that
the gasket is in the filter container's groove.
5. Close the shut-off valve on the water connection
and disconnect the feed water hose from this.
6. Disconnect the purified water hose from another
product or peripheral equipment. If the purified
water tap is installed, you do not need to
disconnect this.
7. Insert the feed water hose in the mixture, making
sure that its mouth is constantly below the surface
level of the liquid until the bucket is empty, see
fig. E.
8. Connect the plug. The water purifier now draws in
the mixture. Pull out the plug after 40 seconds,
before the production of purified water starts.
9. Repeat point 8 until all the liquid has been used.
Pull out the plug.
10. Disconnect purified water hose from the water
purifier by pressing in the grey ring on the
connection and pulling the hose out, see
fig. F.
The water purifier is now put into storage and can be kept in
this way without the risk of freezing. Leave the purified water
hose disconnected from the water purifier. Do not connect
water and electricity until the water purifier is to be
reinstalled.
On reinstallation, the water purifier should:
• be stored at a temperature above 5°C for at least 48
hours.
• be flushed of preserving agent in accordance with
"Flushing".
• be supplied with new filters, see "Replacing the
filters".
E
F
13