Care Instructions - American Standard TOWNSEND 7353.801 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7
SERVICE
Change Direction of the Handle
• Turn valves to OFF position.
• Turn off water supplies.
• Pull HANDLE (1) "UP" firmly to release from ESCUTCHEON (6).
• Remove SCREW (3) and pull off PLASTIC INSERT (2).
• Remove CARTRIDGE NUT (8).
• Remove RETAINING O-RING (4).
• Lift and turn STOP WASHER (5) 90˚. Replace RETAINING
O-RING (4).
• Re-install HANDLE ASSEMBLY.
To Change Cartridge:
• Remove HANDLE (1), ADAPTER (2), SCREW (3) and CARTRIDGE
NUT (8) via steps above.
• Remove cartridge by pulling upward on stem.
Aerator Clean Out
• AERATOR may accumulate dirt causing distorted and reduced
water flow. Remove AERATOR by using the edge of a coin
and rinse to clear any debris.
• If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
8

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
5
90˚
- 3 -
1
6
3
2
4
5
90˚
8
7
M965735 Rev. 1.7 (10/20)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Townsend 7353.841

Tabla de contenido