4. Design and function

4. Design and function
4.1 Description
Design
CE conformity:
GB
89/336/EEC electromagnetic compatibility
2002/95/EC RoHS (restriction of the use of certain hazardous
substances in electrical and electronic equipment)
Accuracy
±1.5 %
(with measuring range -50 ... +50 Pa: ±3 %)
Measuring ranges
-50 ... +50 Pa (-100 ... +100 Pa adjustable via jumper)
0 ... 2500 Pa standard
(-100 ... +100/100/250/500/1000/1500/2000 Pa adjustable via
jumper) or
0 ... 7000 Pa standard
(1000/1500/2000/2500/3000/4000/5000 Pa adjustable via jumper)
Pressure limitation
Maximum pressure: 25 kPa
Burst pressure:
Permissible temperature
Ambient:
Operation: -5 ... +50 °C
Permissible ambient humidity
0 ... 95 % rH, non-condensing

4.2 Scope of delivery

Cross-check scope of delivery with the delivery note.
8
50 kPa
-20 ... +70 °C
WIKA operating instructions air2guide model A2G-50

Publicidad