• Arc correction� Sets higher speed/current arc length.
Caution: when properly adjusted, the arc length is the same for both currents.
• Inductance.
The adjustment can vary from -9.9 to +9.9. Factory setting is zero. If the figure is negative, the impedance drops
and the arc becomes harder, while if it increases, the arc is softer.
To access this function, simply highlight it using the knob B and press it for less than 2 seconds. The display screen
A shows the adjustment bar. The figure can be changed and confirmed by pressing the knob B for less than 2 sec-
onds.
• Burnback AUTO
The adjustment can vary from -9.9 to +9.9. Its purpose is to adjust the length of the wire coming out of the gas
nozzle after welding. A positive figure corresponds to more wire burnt.
The manufacturer adjustment is Auto (Default function)
To access this function, simply highlight it using the knob B and press it for less than 2 seconds. The display screen
A shows the adjustment bar. The figure can be changed and confirmed by pressing the knob B for less than 2 sec-
onds.
32/37
3301278