6
ERROR CODES
Error management is divided into two categories:
1) Hardware errors [E]. These cannot be reset and require the power source to be restarted. They are displayed
on the screen with a red background.
2) Alarms [W] linked to an external condition that can be reset by the user and does not require the power
source to be restarted. These are displayed on the screen with an amber background.
Code
Type
2
[E]
Write error in user data memory
6
[E]
Communication error detected
by panel board
8
[E]
Communication error between
master board and motor control
board
9
[E]
Communication error between
Slave board and Master board
10
[E]
Power output nil (I=0A, V=0V)
42
[E]
Motor speed out of control.
53
[E]
Start button pressed at power
up or during reset due to
overtemperature.
54
[E]
Current not zero when power
source tested
56
[E]
Excessive duration of short-
circuit at output
57
[E]
Excessive current on wire feeder
motor
58
[E]
Firmware upgrade error
60
[E]
Average current above maximum
limit for too long
61
[E]
Phase L1 lower than the
minimum
62
[E]
Phase L1 higher than the
maximum.
74
[W]
Thermal protection triggered
due to excessive temperature in
secondary diode assembly TH1
77
[W]
Thermal protection triggered
due to excessive temperature in
primary IGBT assembly TH2.
80
[E]
"Open" Wire feeder casing open. Check that the wire feeder assembly protective cover is
83
[W]
Incorrect welding torch selection. Indicates that during welding the start button of one of the
36/37
Error Description
Switch the power source off and on. If the problem persists,
contact technical assistance
Switch the power source on and off. If the error persists,
contact technical assistance.
Check connection between panel board (27) and motor control
board (41). Switch the power source on and off. If the error
persists, contact technical assistance.
Check connection between panel board (27) and power board
(68). Switch the power source off and on. If the problem
persists, contact technical assistance
Hardware error, contact technical assistance. Power board 68
failure likely
Check there are no mechanical blockages in the wire feeder
rollers. If the motor turns at an uncontrollable speed, check
the wire feeder wiring. And ensure the motor feed polarity is
correct. If the error persists, contact technical assistance.
Release the torch start button.
Switch the power source on and off. If the error persists,
contact technical assistance.
Switch the power source on and off. If the error persists,
contact technical assistance.
Check there are no mechanical blockages in the wire feeder
rollers. Switch the power source on and off. If the error
persists, contact technical assistance.
Switch the power source on and off. If the error persists,
contact technical assistance.
Switch the power source on and off. If the error persists,
contact technical assistance.
Check the power supply voltage of the machine.
If the error persists, contact technical assistance
Check the power supply voltage of the machine.
If the error persists, contact technical assistance.
Wait until the machine cools down. Check that the air intake
and outlet grilles are not blocked. If the problem persists,
contact technical assistance.
Wait until the machine cools down. Check that the air intake
and outlet grilles are not blocked. If the problem persists,
contact technical assistance.
properly closed and check the wiring. If the problem persists,
contact technical assistance.
torches that is not operating was enabled. If the problem
persists, contact technical assistance.
Action
3301278