Disassemble Instructions
Remove all the parts in the reverse order of the installation steps.
NOTE: To remove the liner, use an L-wrench to pry the retaining
block out of the side panel slot. Do not drag the liner directly.
Spa Bladder Deflation
1. Open the valve cap to deflate the bladder. For quick deflation,
insert the straw (included in the repair kit) into the valve.
2. Once the deflation is completed, re-place the cap back.
Spa Tub and Air Bladder Repair
Use the enclosed repair patch to repair any puncture:
1. Clean and dry the area to be repaired thoroughly
2. Apply the glue to the PVC patch and quickly attach it to the damaged surface. (Glue is not included)
3. Smooth the surface to remove any air bubbles and allow it to dry for 5-10 minutes
NOTE: Glue is not included.
Water / Air Channel Stopper Instructions
A. Air channel stopper
B. Water channel stopper x 2pcs
x 1pc
These caps are used to prevent water leakage when taking off the control box without draining the water.
NOTE: Please make sure to unplug the power pack from the electrical receptacle before the above actions.
B
B
A
15