4
6
7
8
9
NOTE!
When changing the torch body, ensure that only the related systems are installed.
IMPORTANT! When installing the torch body, ensure that it is pushed all the way in and
snaps into place.
10
11
12
13
14
34
Clean the interface at the hosepack using compressed air
Dry the torch body with a cloth
Put the safety cap on the torch body
Do not install gas-cooled torch bodies on water-cooled hosepacks or vice versa.
Attaching the Torch Body
Connect the power source to the grid and switch on
Press the gas-test button on the power source
Shielding gas flows out for 30 s.
Check the coolant flow:
You must be able to see a strong return flow into the coolant container.
Perform a test weld and check the quality of the weld seam
5
180°
1