NOTE: After making the connection, use soapsuds to check if there is leakage on
the pipes. Do not use fire.
Please follow the order below for installation.
1.) Connect the cylindrical male adapter, seal, conical-cylindrical or cylindrical-cylindrical
female gas adapter respectively.
2.) Using the wrench, tighten the connection points to position the pipes.
3.) Using a hard copper pipe or flexible steel pipe, fit carbon joint to the main gas supply.
Warning: Use a soap-water solution to check the pipes for leakage for the last time
and never use fire.
Setting the hob for different types of gas
These instructions are only for qualified and specialist personnel. Installation of the appliance
must be in compliance with the applicable standards.
All procedures must be carried out while the electrical connection is disconnected.
Figure 1
• For conversion, remove the burner caps and flame rings on the hob. Remove the
injectors according to the figure above and replace them with injectors of suitable
diameters specified in the user manual.
• Remove the knobs and rubber seals of the hob, and carry out the procedure using the
flat precision screwdriver in a manner that it faces the valve adjustment screw.
• To set the low flame position, rotate the gas adjustment screw on the valve and set the
minimum gas flow. Fit the burner assembly of the adjusted burner, ignite the burner
and set the knob to minimum position before making this adjustment.
• The flow regulating screw must be loosened when LPG hobs are being converted into
natural gas, and tightened when natural gas hobs are being converted into LPG.
• After converting the hob, fit the rubber seals first and then the knobs to complete the
procedure.
These instructions must be applied by the authorised service provider. The product must be
installed correctly and in accordance with the applicable directives.
The hob must be disconnected from the power supply before carrying out any procedure. The
type label on the hob shows the gas type for which the hob has been designed.