After fitting the injectors, use soap to check for gas leakage. To do this, apply suds
to the bottom side of the injectors.
Put your finger on the injector to block the gas outlet and check if there are
bubbles on the connection point of the injector.
Technical data
Technical Information About Gas Burners
(G20-20 mbar) - (G30-30 mbar) (G30-37mbar)
Burner A
Burner SR
1 kW
1.75 kW
G30-30
G30-30
Mbar LPG
Mbar LPG
(0.50 mm)
(0.65 mm)
G20-20
G20-20
Mbar NG
Mbar NG
(0.72 mm)
(0.97 mm)
G30-37
G30-37
Mbar LPG
Mbar LPG
(0.47 mm)
(0.62 mm)
1. Nitrile/Cylinder head seal
2. Elbow
3. LPG hose inlet
When performing natural gas-LPG conversion, please use the LPG hose inlet shown
in the figure to complete the conversion.
Burner R
Wok Burner
3 kW
(2.5 kW)
Ø 100
G30-30
G30-30
Mbar LPG
Mbar LPG
(0.85 mm)
(0.82 mm)
G20-20
G20-20
Mbar NG
Mbar NG
(1.15 mm)
(1.15 mm)
G30-37
Mbar LPG
(0.80 mm)
16
Wok Burner
Wok Burner
(3.3 kW)
(3.8 kW)
Ø 100
Ø 126
G30-30
G30-30
Mbar LPG
Mbar LPG
(0.89 mm)
(0.98 mm)
G20-20
G20-20
Mbar NG
Mbar NG
(1.28 mm)
(1.35 mm)
G30-37
Mbar LPG
(0.93 mm)