Germany
3. Set to the desired height (from 100 mm to 900 mm in
100 mm steps) depending on the ceiling height.
4. Fasten the extension using the long screws after the
tensioning plate (A) has been placed.
A
5. Fasten the cover.
6. Remove existing hydraulic lines. Do not remove colour
markings.
7. Loosen and turn the T-piece and bracket visible in the
figure.
104
Exchange the supplied hydraulic hoses
1. Place yellow and white on the top of the operating col-
umn.
2. Attach red directly to the unit.
3. Connect blue to K1 of the operating column.
4. Cut the cover panel to length and mount.
8.1.4 First filling with hydraulic oil
When filling the hydraulic system, identify already filled
cylinders (with the sticker "first filling" on the system) and
unfilled cylinders (no sticker on the system).
Lifts with this sticker already have hydraulic oil in the hy-
draulic cylinders.
OPI-POWER LIFT HF 3S 3000-4000-V4.0-DE-EN-FR-ES-IT