3
Technical information
3.1 Technical data
Load carrying capacity:
Loading a lifting arm:
Load distribution:
HF 3S 3000:
HF 3S 3500:
HF 3S 4000:
Standard operating volt-
age:
Motor capacity
HF 3S 3000:
Motor speed:
Hydraulic pump:
Lifting / lowering pressure: 190 bar / 120 bar
Pressure relief valve:
Motor capacity
HF 3S 3500/HF 3S
4000:
Motor speed:
Hydraulic pump:
Lifting / lowering pressure: 300 bar / 190 bar
OPI-POWER LIFT HF 3S 3000-4000-V4.0-DE-EN-FR-ES-IT
HF 3S 3000 = 3,000 kg
HF 3S 3500 = 3,500 kg
HF 3S 4000 = 4,000 kg
A single load from only one
lifting arm may not happen
HF 3S 3000/HF 3S 3500
Max. 2:3 or 3:2 in or
against the drive-in direc-
tion
HF 3S 4000
Max. 1:3 or 3:1 mm or
against the drive-in direc-
tion
Lift/lowering time: approx.
20 s/seamless 0-max 14 s
with 2.68 t
Lift/lowering time:approx.
26 s/seamless 0-max 14 s
with 3.5 t
Lift/lowering time:approx.
26 s/seamless 0-max 14 s
with 4 t
3 ~/N+PE,400 volt, 50 Hz
3 kW
2880 rpm
3.2 cm³
250 bar
3 kW
2880 rpm
2.7 cm³
Pressure relief valve:
Oil volume:
Noise level LpA:
On-site connection:
Optional energy set:
Attention: The Otto arms may only
be used on lifts with 4 tons of steel
construction. The lifting capacity
will be reduced to 3500 kg when
the Otto arms are used.
3.2 Safety devices
• Over-pressure valve
Hydraulic system fuse against over-pressure.
• Check valve
Secure the vehicle against unauthorised lowering.
• Main switch with curtain lock device
Fuse to prevent unauthorised use.
• Two independent cylinder systems (each with
a command, follow system)
Secure against unauthorized lowering of the lift.
• Deadman controls
Lift movement stops when the operating lever is re-
leased.
• CE-STOP
• Lifting arm block
Secures the lifting arm against horizontal movement in
a lifted condition.
• Operating lever with curtain lock device
Fuse to prevent unauthorised use.
310 bar
Approx. 10 litres (HLP32)
≤ 70 dB
3~/N+PE, 400 V, 50 hz
with 16 A fuses, slow,
according to
VDE regulations
Pneumatic connection:
for compressed air
6-10 bars
Socket: 220 V/50 Hz
79