MAIN COMPONENTS (fig. 3)
Codice/Code 8117080
Modello/Model MURELLE EQUIPE 220 BOX ErP
Matricola/Serial n. 9999999999
PAR 1 = 69 (G20) / 71 (G31)
PAR 2 = 9
KEY
1 System return manifold
2 Gas tap
3 System supply manifold
4 Gas valve
5 Fan
6 Ignition electrode
7 Primary exchanger
8 Ignition transformer
9 Control panel
10 Heating return probe (SR)
11 Heating supply probe (SM)
12 Safety thermostat 100°C
13 Detection electrode
14 Pump high efficiency
15 Check valve
16 3-way drain tap
17 Gas manifold
18 Diaphragm in suction
CAUTION: To access the control panel
(9) remove the two screws which secu-
re it to the support bracket and turn the
panel downwards.
1.6
TECHNICAL DATA PLATE (fig. 3/a)
YEAR OF CONSTRUCTION
WATER CONTENT IN BOILER
HEAT OUTPUT MAX (80-60°C)
HEAT OUTPUT MAX (50-30°C)
MAX OPERATING PRESSURE
HEAT INPUT MAX D.H.W.
MAX OPERATING PRESSURE D.H.W.
MAX POWER ABSORBED
COUNTRIES OF DESTINATION
MODEL
SERIAL NUMBER
HEAT INPUT MAX
CONTENTS D.H.W.
D.H.W. FLOW RATE
POWER SUPPLY
CATEGORY
TYPE
CODE
PIN NUMBER
DIRECTIVE OF REFERENCE
HEAT INPUT MIN
HEAT OUTPUT MIN (80-60°C)
HEAT OUTPUT MIN (50-30°C)
MAX OPERATING PRESSURE
HEAT INPUT MIN D.H.W.
MAX OPERATING PRESSURE D.H.W.
ELECTRICAL PROTECTION GRADE
NOx CLASS
CODE GAS COUNCIL NUMBER (UK)
CERTIFICATION WRAS (UK)
TYPE OF GAS
GAS SUPPLY PRESSURE
CLASSIFICATIONS
ES
ES
EN
EN
Fig. 3