Descargar Imprimir esta página

ELICA EBS630SS Guía De Instalación, Uso Y Mantenimiento página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

CFM Reduction System
Before operating your hood:
Some States and Provinces of the US & Canada restrict the
maximum exhausting airflow of range hoods�
Airflow is measured as cubic feet per minute (CFM)�
These maximum levels allowed are detailed in the local code
of your area� Please check local codes to find out if you need
to restrict the maximum airflow of your hood� If your local
code mandates a maximum airflow level below the maximum
airflow of this hood (i�e� 600 CFM), please execute the proce-
dure below to reduce the maximum airflow�
With blower and light turned Off
• Press and hold both buttons at the same time for 3 sec you
will hear a beep and the icon lights (no edge) will illuminate
for 3 seconds�
• This action will disable speed 4 and effectively lower the
maximum airflow to > 300 CFM�
• Locate the CFM certification sticker in the hardware pack�
• Peel and Affix this sticker to a visible area in the blower�This
sticker provides official certification to your local inspector
that this hoods maximum airflow has been reduced to >
300 CFM�
Mainteinance
Cleaning
Do not spray cleaners directly to the control while cleaning the
Hood� The cooker hood should be cleaned regularly (at least
with the same frequency with which you carry out maintenance
of the fat filters) internally and externally� Clean using the
cloth dampened with neutral liquid detergent� Do not use
abrasive products� Do not use chlorine base cleaners�
DO NOT USE ALCOHOL!
I
WARNING:
Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire risks�
Therefore, we recommend oserving these instructions�
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate maintenance
or failure to observe the above safety recommendations�
Grease Filter
Traps cooking grease particles�
This must be cleaned once a month using non aggressive
detergents, either by hand or in the dishwasher, which must be
set to a low temperature and a short cycle� When washed in
a dishwasher, the grease filter may discolour slightly, but this
does not affect its filtering capacity�
To remove the grease filter, pull the spring release handle�
A. Spring release handle
10
Indicators of filter saturation:
At regular time intervals, the hood indicates the need of
performing filter maintenance�
Blower button icon blink (no edge):
Perform grease filter maintenance�
Light button blink (no edge):
Perform activated charcoal filter maintenance�
Reset of filter saturation indicators:
With blower Off press and hold the blower button for 3 sec�
Activation of saturation indicator activated charcoal filter:
NOTE: This operation must be performed with the hood off�
This indicator is normally deactivated; press and hold the
blower button for 3 sec� to activate the function: the button
blinks for 1 sec�
To deactivate the function, press and hold the blower button
for 3 sec�, the button blinks for half a sec�
Replacing a LED Lamp
The LED lights are replaceable by a service technician only�
See "Who to contact" section in the warranty for service
contact information�
Charcoal filter
NOTE
When used in recirculation mode, To Reduce the Risk of Fire
and Shock use only conversion kit model KIT02766�
If the model is not vented to the outside, the air will be
recirculated through disposable charcoal filters that help
remove smoke and odors�
1
2
NOTE: The charcoal filters cannot be cleaned� It should be
replaced every 4-6 months (depending on hood usage)�
A
Cover the grill that protects the suction motor with the
carbon filter so that the slots on the filter correspond to
the pins on the sides of the motor protection grill�
Turn the carbon filter clockwise to block them (bayonet
fixing)�

Publicidad

loading

Este manual también es adecuado para:

Ebs636ss