Electrical & Installation Requirements
IMPORTANT
Observe all governing codes and ordinances�
It is the customer's responsibility:
• To contact a qualified electrical installer�
• To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 — latest edition*, or CSA Standards C22�1-94, Canadian
Electrical Code, Part 1 and C22�2 No�0-M91-latest edition**
and all local codes and ordinances�
• If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate�
• Do not ground to a gas pipe�
• Check with a qualified electrician if you are not sure range
hood is properly grounded�
• Do not have a fuse in the neutral or ground circuit�
IMPORTANT
• Save Installation Instructions for electrical inspector's use�
• The range hood must be connected with copper wire only�
• The range hood should be connected directly to the fused
disconnect (Or circuit breaker) box through metal electrical
conduit�
• Wire sizes must conform to the requirements of the
National Electrical Code ANSI/NFPA 70 — latest edition*,
or CSA Standards C22�1-94, Canadian Electrical Code Part
1 and C22�2 No� 0-M91 - latest edition** and all local codes
and ordinances�
• A U�L�- or C�S�A�-listed conduit connector must be provided
at each end of the power supply conduit (at the range
hood and at the junction box)�
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park Quincy,
Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575
Product Dimensions
F
G
A
4
E
C
D
B
• If provided with an electrical plug, connect the hood to
a receptacle that complies with current regulations and
placed in an accessible position� Where an electrical plug
is not provided (direct connection to electrical network)
or the plug will not be in an accessible position after
installation, place an approved bipolar switch in accessible
position that provides full disconnection under overvolta-
ge category III conditions, in accordance with local wiring
rules�
BEFORE INSTALLING THE HOOD
1
For the most efficient air flow exhaust, use a straight run
or as few elbows as possible�
CAUTION: Vent unit to outside of building, only�
2
At least two people are necessary for installation�
3
Fittings material is provided to secure the hood to most
types of walls/ceilings, consult a Qualified Installer, check
if they perfectly fit with your cabinet/wall�
4
Do not use flex ducting�
5
COLD WEATHER installations should have an additional
backdraft damper installed to minimize backward cold
air flow and a nonmetallic thermal break to minimize
conduction of outside temperatures as part of the
ductwork� The damper should be on the cold air side of
the thermal break�
The break should be as close as possible to where the
ducting enters the heated portion of the house�
Make up air: Local building codes may require the use of
Make-Up Air Systems when using Ducted Ventilation Systems
greater than specified CFM of air movement� The specified
CFM varies from locale to locale� Consult your HVAC profes-
sional for specific requirements in your area��
EBS630SS
A
30" (76�2 cm)
B
C*
Max: 42
Min: 28
D**
Max: 38
Min: 28
E
F
G
*
Ductless (Recirculating) version
** Ducted version
Models
EBS636SS
36" (91�4 cm)
19
" (50 cm)
11
1 6
" (107 cm)
1
8
" (72 cm)
6
1 6
" (97 cm)
3
1 6
" (72 cm)
6
1 6
6" (15�24 cm)
7
" (18�3 cm)
3
1 6
8
" (20�8 cm)
3
1 6

Publicidad

loading

Este manual también es adecuado para:

Ebs636ss