A. Centerline
B. Fastener locations
C. Mounting height reference (hood bottom line)
4
Mark centers of the fastener locations through the
template to the wall�
IMPORTANT: All screws must be installed into wood�
If there is no wood to screw into, additional wall framing
supports may be required�
5
Remove the template�
6
Drill
⁄
" (4�8 mm) pilot holes at all locations where screws
3
1 6
are being installed into wood�
7
Install the 2 - 5 x 45 mm mounting screws� Leave a
(6�4 mm) gap between the wall and the back of the screw
head to slide range hood into place�
⁄
"
1
4
(6�4 mm)
Install Range Hood
Connect Vent System
1
Remove protective film from hood and duct covers�
2
Install transition on top of hood (if removed for shipping)
with 2 - 3�5 x 9�5 mm screws using the Torx 10 adapter
A
B
3
Remove both exterior and interior wood logs by removing
the screws inside the hood
Install Range Hood
1
Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood�
A
B
A
C
B
A. Vent transition
B. 3.5 x 9.5 mm screw
Screws
A. Mounting screws
B. Mounting slots
Vent cover bracket installation
1
Attach vent cover bracket to wall flush to the ceiling using
2 - 5 x 45 mm screws�
A. 8 x 40 mm anchors
B. Centerline on wall
Complete preparation
1
Determine and make all necessary cuts in the wall for the
vent system� Install the vent system before installing the
hood� See "Venting Requirements" section�
2
Determine the required height for the home power supply
cable and drill a 1¼" (3�2 cm) hole at this location�
3
Run the home power supply cable according to the
National Electrical Code or CSA Standards and local codes
and ordinances� There must be enough ½" conduit and
wires from the fused disconnect (or circuit breaker) box to
⁄
"
1
4
make the connection in the hood's electrical terminal box�
NOTE: Do not reconnect power until installation is complete�
4
Use caulk to seal all openings�
2
Mark with a pencil the lower mounting holes location�
3
Uninstall the hood assembly, and drill
holes at marked locations�
4
Hang the range hood again on 2 upper mounting screws�
5
Level the range hood and tighten upper mounting screws�
6
Install 2 - 5 x 45 mm lower mounting screws and tighten�
Use the optional wall anchors if needed�
For vented installations only:
1
Fit vent system over the exhaust outlet�
2
Measure from the bottom of the air deflector to the
bottom of the hood outlet� Cut the ductwork at the
measured dimension�
3
Seal connection with clamps�
4
Check that back draft dampers work properly�
A
C
D
B
C. Vent cover support bracket
D. 5 x 45 mm screws
⁄
" (4�8 mm) pilot
3
1 6
Roof outlet
Wall
outlet
Dimension
to measure
7