2.0 CONNECTING TO THE FLUE
The gas appliances are provided with a flue for eliminat-
ing the residuals of combustion.
This flue must be connected as illustrated in figure as
established by the installation rules.
Forced fumes evacuation type A1
The appliance is of the A1 type. It must to be installed
in sufficiently ventilated rooms to prevent the possibility
of unacceptable concentrations of substances harmful to
health in the room in which the appliance is installed,
made in accordance with national and local laws and
regulations in force.
Indicatively the flow rate of an air aspirator connected
directly to the external environment is 35 m
/h for each
3
kW of gas power installed.
The appliance must be installed in sufficiently ventilated
rooms to ensure the air flow necessary for combustion,
in accordance with the national and local laws and reg-
ulations in force.
2.1 PLUMBING – WATER DRAINAGE
Drainage for the water is at the back of the oven and must be connected
directly to the end of the stainless steel drainpipe.
The drain must have no trap and be made in rigid pipes that can withstand
a temperature of 110°C.
Under no circumstances must pipe diameter be reduced. The actual pipe
should be at atmospheric pressure with the appropriate funnel type air
intake.
If the drainpipe is clogged for any reason steam can escape from the door
and bad smells can be created inside in the oven.