3.1 REPLACING SPARE PARTS
The replacement of damaged parts must be done only by qualified personnel.
To request the manufacturer parts to be replaced must be provided the oven model and serial number.
These data can be found on the rating plate attached to the oven.
Before starting to replace spare parts make sure, for safety reasons, that the electricity main switch is off
and that the water on-off valve are closed.
3.2 CHECKING THE FUNCTIONS
After completing the installation of the oven is necessary to perform a leak test to the water network.
The installer must check with suitable measurement instruments that the air noise emissions have
a level of sound pressure type weighed A, less than 70 dB (A).
IMPORTANT:
Before the operator turns the oven on and uses it for any cooking or washing cycle, it is necessary that the installer
or a qualified technician checks all the connections have been done up to the instructions stated in our manual.
The technician or the installer must therefore check as follows:
• The oven must stand (horizontal position) and be fixed on a stand or a shelf, that can guarantee stability.
• Wiring connection must be effected according to the directives and the feed cable section must be no lower than
the one indicated in the manual.
• Pressure and hardness of the water must comply the values indicated in this manual;
• If the oven is supplied with drain pipe, this must be connected properly and the materials used should withstand
the working temperature.
After you have checked everything, open the water on-off valve, eventually the gas on-off valve and the protection
switch, all installed upstream.
The installer must check the proper functioning of the oven and give to the operator necessary instructions for a
correct use of the oven, and also verify that the operator owns a copy of this manual.
3.3 GAS OVENS: SOSTITUTION OF NOZZLES
TABLE FOR NOZZLE SUBSTITUTION
THERMIC NOMINAL POWER
10.0 kW
13.5 kW
20.0 kW
You have to close the gas tap before make any operation.
The label ISO 3864-1 here on the side must be stuck on a visible surface, 1,6 mt
height from the ground.
On floor models, the label is already stuck in the suitable position.
On table models, the label is supplied along with the documentation and must be
stuck after installation on a visible part of the appliance at 1.60 mt from the ground.
The installer must verify proper operation of the oven, providing the necessary instruc-
tions to the customer and give this instruction manual that the user must follow carefully.
NOZZLES
G30 30 mbar
G20 20 mbar
G30 28..30 mbar
G30 50 mbar
G20 20 mbar
G25 25 mbar
G25 20 mbar
G30 28..30 mbar
G30 50 mbar
G20 20 mbar
G25 25 mbar
G25 20 mbar
G31 30...37 mbar
G31 50 mbar
G31 30...37 mbar
G31 50 mbar
15
EN
MARKING
80
120
90
80
140
150
155
110
95
175
185
195

Publicidad