Air losses
These can be caused by poor tightness of a union – check all
unions, wetting them with soapy water.
Compressor turns but does not load
Coaxial compressors: (fig. 12)
- this may be due to failure of the valves (C1 – C2) or of a seal
(B1 – B2): replace the damaged part.
Pulley drive compressors: (fig. 13)
- this may be due to failure of the valves F1 and F2 or of a
seal (D1 – D2): replace the damaged part.
- Check if there is too much condensate water inside the tank.
IMPORTANT
- Do not on any account unscrew any connection while the
tank is pressurised – always check if the tank is pressure
free.
- Do not drill holes, weld or purposely deform the compressed
air tank.
- Do not do any jobs on the compressor unless it is off.
- Temperature in operating ambient: 0°C +35°C.
- Do not aim jets of water or inflammable liquids on the
compressor.
- Do not place inflammable objects near the compressor.
- Never aim the air jet at people or animals
- Do not transport the compressor while the tank is
pressurised.
- Be careful with regard to some parts of the compressor such
as the head and delivery tubes, as they can reach high
temperatures. Do not touch these parts to avoid burns.
- Transport the compressor, lifting or pulling it with the
appropriate grips or handles.
- Keep children and animals well away from the machine
operating area.
- If using the compressor for painting:
a. Do not work in closed environments or near to naked flames
b. Make sure there is adequate exchange of air at the place of
work
c. Protect your nose and mouth with an appropriate mask. (fig.
14)
- Do not put objects or your hands inside the protective grilles
to avoid injury to yourself or damaging the compressor.
PROCEDURE
Check pump oil level
Oil leak inspection
Drain condensation in air tank(s)
Inspect guards/covers
Check for unusual noise/vibration
Check for air leaks
Clean exterior of compressor
Inspect air filter
Check safety relief valve
Inspect bel tension
Change pump oil
Replace air filter
The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months, whichever comes first. Open the pump oil
cock and replace pump oil. As regards the engine, follow instructions in the engine manual. Every 2 years, an Authorized Service Technician
should check the check valve, intake valves and delivery valves.
17
- Do not use the compressor as a blunt object toward things or
animals, to avoid serious damage.
- When you have finished using the compressor,always switch
it off.
MAINTENANCE
WARNING: Remove the compressed air from the air tank
Read the instruction manual before performing maintenance.
The following procedures must be performed when stopping
the compressor for maintenance or service.
A) Turn off the compressor.
B) Disconnect spark plug wire from engine.
C) Open all drains.
D) Wait for this compressor to cool down before starting
service.
1. Cleaning the air intake filter
This filter is designed to clean air coming into the pump
(fig.9). To ensure the pump continually receives clean,
cool, dry air supply this filter must always be clean and
ventilation opening must always be free from obstructions.
WARNING: Never
CAUTION:
NOTE:
2. Draining tank:
Gradually open the drain valve, and drain out the air in the
tank. Close tightly when drained.
3. Oil change-oil topping off (fig.10).
4. Maintenance chart.
MAINTENANCE CHART
AFTER USE
DAILY
X
X
X
X
X
X
X
before performing the maintenance operations.
Allow
the
compressor
performing
the
maintenance
Always stop engine and pull out the spark plug
cap to prevent any sudden start of the engine
and remove this compressed air from the air
tank
before
performing
operations.
clean
filtering
flammable liquid or solvent.
Do not operate without the intake filter.
Replace the filter element when it becomes dirty.