ENGLISH
7.
Install a control valve in the return line between the first and second tee or prior to the vessel inlet on the bypass
line to control the water flow through the bypass.
8.
Hand tighten all unions, sensors, and collars.
Be careful not to get finger caught between inlet union and plug when tightening as this may cause an injury.
9.
Fully open any closed valves, including the control valve, and start the pump diverting water through the new
bypass.
10. Check the vessel and system for leaks.
11. Adjust control valve so that flow rate through the vessel is between a minimum of 30 gpm (114 lpm) and a
maximum of 120 gpm (455 lpm).
3.6
Split-Return Installation
If the vessel is used with a water feature line system, it must be installed in a split-return configuration or vessel
damage may occur.
1.
Make sure the pool pump is turned off.
2.
Remove the temporary cap on the cartridge side of the vessel, and install the Nature
in the box. Do not throw out the cap. It will be used for winterization of the system.
3.
Locate a suitable section of pipe to install the vessel that conforms to the installation requirements outlined in
Section 3.2.
4.
Install a 3-way valve in the return line to allow water to be diverted/restricted to the Nature
water feature line.
5.
Fully open any closed valves, including the 3-way, to allow unrestricted flow to the Nature
water feature line.
6.
Hand tighten all unions, sensors, and collars.
Be careful not to get finger caught between inlet union and plug when tightening as this may cause an injury.
7.
Start the pump and allow water to pass through the newly plumbed system. Check for any leaks.
8.
Make sure the flow rate to the Nature
3.7
Installing the FUSIONM or AquaLink
The control/power center is not to be considered as suitable for use as service equipment. Therefore, it is required
to have the appropriate means of disconnection, circuit isolation, and/or branch circuit protection installed upstream
of the power center.
NOTE The control/power center should be located at or near the equipment pad.
1.
Locate the control/power center at least five (5) feet or more away from pool/spa and five (5) feet off the ground.
All national, state, and local codes are applicable.
|
Zodiac
Nature
2
Fusion soft
®
®
CAUTION
CAUTION
Fusion Soft does not drop below 30 gpm (114 lmp).
2
RS PureLink
®
CAUTION
Installation and Operation Manual
2
start-up cartridge included
TM
Fusion Soft and
2
Fusion Soft and
2