Descargar Imprimir esta página

Zodiac Nature2 Fusion soft Manual De Instalación Y Operación página 31

Ocultar thumbs Ver también para Nature2 Fusion soft:

Publicidad

Idiomas disponibles

Idiomas disponibles

Press the Valve Select button to choose either Pool Mode to change pool chlorine production, or Spa Mode to change spa
chlorine production.
Press the Filter Pump button to turn on the pump and apply power to the sanitizing system.
Control/Power Center User Interface
Press the down arrow button A or the up arrow button B to change the chlorine production rate in 5% increments. Generally,
adjustments to production should be made in 10% increments.
AquaLink RS Control System
Press the Mode Select button to put the AquaLink
Press the Mode Select button again to place it back into Auto mode.
NOTE The AquaLink RS control system must be in pool mode to change the pool chlorine production rate setting;
and it must be in spa mode to change the spa chlorine production rate setting. Use the valve select button to
switch between the two (2) modes. The system must be cycled through SERVICE, TIME OUT, then back to
AUTO to accept the Pool Setting versus the Spa Setting.
5.2
Reading the Display
CELL ON
The CELL ON indicator shows that the cell has been turned on. Some reasons for the CELL ON indicator not being on
during normal operation, are: CHLORINE PRODUCTION RATE set to 00%, CHLORINE PRODUCTION RATE set to
less than 100% and CELL RESTING appears during cell rest period, NO FLOW condition, two (2)minutes before automatic
cleaning cycle, low temperature cut off has been activated, or a service related problem such as a salinity level below 2.0 gpl
or salinity level too high.
CELL RESTING
During the normal chlorine production cycle when the unit is set for less than 100%, the cell will periodically rest; that is,
the unit will not make chlorine. The CELL RESTING indicator shows that the cell has been turned off by the control power
center.
FLOW or NO FLOW Indication
When the control/power center determines that water is flowing past the flow/temp/salinity sensor, the FLOW indicator is
displayed. When no flow is detected, NO FLOW is displayed on the LCD and the cell is turned off.
CELL REVERSING
The automatic cleaning cycle is in progress. The cleaning cycle is factory set and cannot be adjusted. Cell Reversing does
not interrupt the production of chlorine.
SALINITY
Salinity is displayed along with the gpl (grams per liter) indicator, when the SALINITY button (C) is depressed. If a reading
of HH appears, the salinity is above 4.5 to 6.5 gpl (depending on pool temperature) and is too high to measure correctly (at
normal temperatures). Maintain salinity between 3.0 and 3.5 gpl. See Section 4.
ADD SALT
The ADD SALT indicator comes on when the flow/temp/salinity sensor determines that the salinity level of the pool water is
too low. Maintain Salinity between 3.0 and 3.5 gpl.
|
Zodiac
Nature
2
Fusion soft
Installation and Operation Manual
®
®
®
RS in the Time Out mode.
Page 31
ENGLISH

Publicidad

loading