2.4
Electrical Specifications
Nature
Fusion Soft 700 Connected to FUSIONM
2
Input
120 VAC, 50/60 Hz, 1.5 AMPS
240 VAC, 50/60 Hz, 0.75 AMPS
Output
22-30 VDC @ 3 AMPS maximum
Chlorine
0.625 lb / day (283 gm / day)
External
ORP/External Control Connector
Control
AquaLink
RS485 Connector
®
Option
The FUSIONM saltwater chlorinator electronics are factory wired for 240 VAC service. If the available
electrical service is 120 VAC, then the power supply wiring must be changed to operate on 120 VAC as shown in
Figures 11 and 13.
The chlorinator electronics are powered from the LOAD SIDE of the pool circulation pump relay;
therefore, if the available electrical service is 120 VAC, then the pump must also be wired for 120 VAC.
Section 3.
Installation Instructions
FOR YOUR SAFETY: This product must be installed and serviced by a professional pool/spa service technician
as described on the front cover of this manual. The procedures in this manual must be followed exactly. Failure
to follow warning notices and instructions may result in property damage, serious injury, or death. Improper
installation and/or operation will void the warranty.
When using electrical products, basic precautions should always be followed, including the following:
• RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before at-
tempting installation or service, ensure that all power to the device is disconnected/turned off at the
circuit breaker.
• Grounding is required. The unit should be installed by a qualified service representative and should
be properly grounded and bonded. (See Section 3.8, Grounding and Bonding).
• Install to permit access for servicing.
• Read Section 1, Safety Information. Before attempting any electrical wiring, be sure to read and
follow Safety Instructions. Wiring should only be attempted by a qualified professional.
|
Zodiac
Nature
2
Fusion soft
Installation and Operation Manual
®
®
Nature
Fusion Soft 1400 Connected to FUSIONM
2
120 VAC, 50/60 Hz, 2.5 AMPS
240 VAC, 50/60 Hz, 1.25 AMPS
22-30 VDC @ 6 AMPS maximum
1.25 lb / day (567 gm / day)
ORP/External Control Connector
AquaLink RS485 Connector
CAUTION
WARNING
WARNING
Page 9
ENGLISH