Page 22
ENGLISH
3.12 Connection to the AquaLink
The Jandy
AquaLink RS is a multi-function pool controller that can fully control the function of the Nature
®
Soft chlorine generator. The chlorine generator user interface will display "JA" when any of its buttons are pressed
while the AquaLink RS is in control. Adjustment of the chlorine production rate or Boost mode can be controlled from
the main menu of the AquaLink RS controller (All Button, OneTouch™, or PDA). Boost mode can also be activated
from the chlorine generator user interface while the AquaLink RS is online. Refer to the AquaLink RS Operation
Manual (or AquaLink RS PDA Operation Manual) for more information. The chlorine generator's user interface will
display temperature, salinity, service codes, and LED indicators as normal.
NOTE The Nature
Fusion Soft and PureLink
2
versions JJ or later.
3.12.1 Wiring Nature2 Fusion Soft Power Pack to a Jandy AquaLink RS
In the AquaLink RS power center enclosure, wire the Nature
LOAD SIDE of the filter pump relay (see Figure 14).
To Filter Pump
240 VAC
Figure 14.
Power connection between AquaLink RS enclosure and Nature
The Jandy AquaLink RS and Nature
to 500 feet (150 m) apart. Any outdoor rated four (4) conductor cable, minimum 22 AWG, can be used. Locate the
appropriate screw terminals on the circuit board according to Figure 15. Wire the Nature
4-pin terminal bar to the AquaLink RS red 4-pin terminal bar.
Red, 4-Pin
Terminal Bar
OPTIONAL
AquaLink RS Power Center
Figure 15.
Wiring Nature
Zodiac
Nature
®
RS Control System
®
electronics will communicate with AquaLink RS using firmware
TM
AquaLink RS Power Center
(High Voltage Area)
Filter Pump Relay
Aux. 3 Relay
Fusion Soft use a four (4) wire connection to communicate and can be wired up
2
4 3 2 1
Chlorine Generator
Power Interface
Board
Fusion Soft Control Center to an AquaLink RS Control System
2
|
2
Fusion soft
Installation and Operation Manual
®
Fusion Soft power pack input power directly to the
2
To Breaker
Panel
NOTE
The screw terminals are removable to aid in
installation.
IMPORTANT
Attach the Nature
the like-numbered screw terminals on both the
Nature
Fusion Soft and AquaLink RS as shown in
2
Figure 14.
Nature
Fusion Soft Power Pack
2
Fusion Soft enclosure.
2
Fusion Soft from the red
2
Fusion Soft wires to
2
Fusion
2