Descargar Imprimir esta página

Zodiac Nature2 Fusion soft Manual De Instalación Y Operación página 34

Ocultar thumbs Ver también para Nature2 Fusion soft:

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 34
ENGLISH
5.4.3 Apply Power
1.
Turn on the pool pump. When the chlorinator is first turned on (cold), the unit will beep. Next it will self-
calibrate the flow/temp/salinity sensor. After going through an internal test and calibration, the LCD will
display the current setting for chlorine production (00% to 100%). During the calibration period "Wait"
will appear. "Wait" means the unit is self calibrating and doing internal testing. This process usually takes
less than six (6) minutes.
2.
Check salinity level by pressing the SALINITY button (C) . It should read between 3.0 gpl and 3.5 gpl. If
it does not, then press the SALINITY button (C) two (2) or three (3) more times until the salinity reading
stabilizes.
NOTE If still less than 3.0 gpl refer to Tables 1 and 2 and adjust salt concentration level. (Maintain the
Recommended Salinity Level of 3.0 to 3.5 gpl). If salinity is below 2.0 gpl the system will automatically
turn the electrolytic cell off until the salinity is raised above 2.0 gpl. Operating with a low salt
concentration will damage the electrolytic cell. Likewise, if salinity is above the range of measurement
the system will automatically turn the electrolytic cell off until the salinity is lowered to a measurable
level. Operating with high salt will damage the power center. If salinity is greater than 3.5 gpl, see
Section 7, Troubleshooting.
3.
Adjust the chlorine production to 50% by pressing the arrow buttons (A) or (B) .
4.
After 24 hours, use a reliable test kit to measure the pool water for free active chlorine. The ideal range to
maintain is 1 - 3 ppm. If the chlorine content of the pool water is
by pressing the up arrow button
chlorine production by pressing the down arrow button
in smaller increments (5%) as the correct chlorine level is approached.
5.
Due to a varying chlorine demand of pool water, it may take a few days to determine the correct pool pump
operating time and chlorine production percentage setting for your pool. Continue adjusting as necessary,
allowing 24 hours between adjustments until the chlorine content of the pool water has stabilized at 1 - 3
ppm.
5.5
Operating in Winter
See Section 6.7, Winterizing.
5.6
Recommendations
• DO List
Read and keep your manual in a safe place.
Replace the start-up cartridge within 30 days and again every six (6) months.
Increase chlorine production rate before a large number of bathers enter the pool and return to normal afterwards.
Increase chlorine production rate when temperature goes up.
Increase chlorine production rate when the number of bathers goes up.
For outdoor pools only, use stabilizer (cyanuric acid) to stabilize chlorine in pool.
Mount power center in shade or out of the direct sunlight whenever possible.
Decrease production rate when temperature goes down (for example, in the Fall and Winter seasons).
Take pool water sample to a qualified service representative once per month.
|
Zodiac
Nature
2
Fusion soft
Installation and Operation Manual
®
®
(B) . If the chlorine content of the water is
too low, increase chlorine production
too high, decrease
(A) . Adjust in 10% increments initially then

Publicidad

loading