Page 32
ENGLISH
SERVICE and Service Code
The SERVICE indicator will turn on whenever the control system detects a problem that requires attention. The SERVICE
indicator is accompanied by a service code displayed on the front panel, displayed as a three (3) digit code. The service
code(s) are displayed twice per minute with an audible alarm.
NOTE See Section 7.2 Service Codes. Problems can range from insufficient salinity to the DC cord not connected.
Audible Alarm
An audible alarm (beep) sounds once per hour, and only for the first service code, when a SERVICE condition is detected.
The alarm can be cleared by pressing and holding the SALINITY button (C) for five (5) seconds. The audible alarm can be
cleared for 24 hours or until the power to the unit is turned off and back on whichever comes first. However, the audible
alarm will return if a new problem is detected.
NOTE The audible alarm can be permanently disabled by removing the jumper from J2 on the control/power center
power interface board
Audible Alarm Volume Control
Audible alarm operation and volume control can be adjusted. To adjust volume control, press and hold the TEMPERATURE
button (D) for 15 seconds. The system will beep once when pressed, once after 10 seconds and once after 15 seconds.
Release the key after the third beep. Press the SALINITY button (C) within five (5) seconds to enter the temperature change
screen.
NOTE The boost cycle is normally activated after 10 seconds, however, if the key is held down until after the third
beep at 15 seconds, the Boost mode will not be changed.
The system will display a '1' followed by 'F' or 'C'. Press the TEMPERATURE button (D) to move to the second parameter
screen. The screen will display a 0, and the alarm volume will be fully reduced. The system will occasionally show a
'2' to display the screen number. Press the arrow button B to increase the volume and the arrow button A to reduce the
volume. The volume increments from 0 to 100 in 20 steps. After each press of the arrow buttons, the alarm will activate to
demonstrate the current volume level. When the alarm volume has been adjusted to the desired setting, press the SALINITY
button (C) to confirm the new alarm volume setting. The change will be stored in permanent memory. If you do not wish to
keep the change, wait five (5) seconds, and the change screen will 'time out' and return to normal operation without keeping
any changes to the system. Any changes made to the alarm volume will NOT be saved if this occurs.
5.3
Operation
Before attempting to operate the device, refer to Section 4, Pool Water Preparation. Also, do not adjust Chlorine
production above 00% until it is certain that salt has been dissolved in pool. Operating without salt will damage the
Electrolytic Cell.
Use of an external pool pump timer is not required with the saltwater chlorinator power/power pack. The chlo-
rinator is designed to supply a sufficient amount of chlorine to sanitize pool water on a daily basis. If the system is op-
erated for 24 hours a day at a 100% production rate, more chlorine would be generated than would be needed by most
pools (0.5 - 3.0 ppm). The chlorinator control system has an internal timer which cycles the electrolytic cell on and
off depending on what percent is set for the Chlorine Production Rate. For instance, at 100% the cell is on at all times
while the pump is running. When the system is set at 90%, the cell will rest 10% of the time which helps prolong the
cell life. In order to fine tune the chlorine production for any size pool just increase or decrease the Chlorine Produc-
tion Rate from 00% to 100% until the chlorine level in the pool stabilizes between 0.5 - 3.0 ppm while the pump is
running (see Section 5.4.3, "Apply Power" steps 1-5).
NOTE The chlorinating system only operates when the pump is running. During hot weather months you may need
to increase pump run time to allow sufficient chlorine production.
|
Zodiac
Nature
2
Fusion soft
Installation and Operation Manual
®
®
CAUTION