To set the device as "RS485 network slave", or Mesh Network slave (WiFi models only):
• Press simultaneously the SPEED - MODE - FUNCTION buttons.
• Press in sequence the following buttons: MODE - MODE - SPEED - SPEED - FUNCTION - FUNCTION.
• Press the SPEED button within 20 sec.
• All speed LEDs from 1 to 5 will blink briefly to indicate that the device has been set as the Slave.
• If the SPEED button is not pressed within 20 sec, the device will return to normal operation without making any
changes to the settings.
To set the device as "Even Unit":
• Press simultaneously the buttons: SPEED - MODE - FUNCTION
• Press in sequence the buttons: SPEED - SPEED - FUNCTION - FUNCTION - MODE - MODE.
• Press the SPEED button within 20 sec.
• All speed LEDs from 1 to 5 will blink briefly to indicate that the device has been set as an even numbered unit.
• If the SPEED button is not pressed within 20 sec, the device will return to normal operation without making any
changes to the settings.
To set the device as an "Odd Unit":
• Press simultaneously the SPEED - MODE - FUNCTION buttons.
• Press in sequence the buttons SPEED - SPEED - FUNCTION - FUNCTION - MODE - MODE.
• Press the FUNCTION key within 20 sec.
• All speed LEDs from 1 to 5 will blink briefly to indicate that the device has been set as an odd-numbered unit.
• If the Function button is not pressed within 20 sec, the device will return to normal operation without making
any changes to the settings.
Parameters programming Mesh network (WiFi models only)
The WiFi module creates a mesh wifi network to synchronize the units. The mesh network is identified by a particular
SSID (Service Set Identifier), which will be generic by default during installation and will become unique for each
particular network once installation is completed.
To set the SSID (Service Set Identifier) of the WiFi mesh network
From the factory setting the machines are set as SLAVE, it is therefore necessary to set a unit as
!
MASTER by pressing the speed - mode - function buttons simultaneously by pressing the MODE
- MODE - SPEED - SPEED - FUNCTION – FUNCTION buttons in sequence and then the MODE
button .
• Press simultaneously the SPEED - MODE - FUNCTION buttons on the MASTER device.
• Press the MODE - MODE - SPEED - SPEED - MODE - MODE buttons in sequence.
• Press the SPEED button within 20 seconds
• All speed LEDs from 1 through 5 will briefly blink to indicate that SSID = VOR_XXXXXXXX has been set on
EACH SINGLE UNIT IN THE NETWORK
• If the SPEED button is not pressed within 20 seconds, all SPEED LEDs from 1 to 5 will light up for 1 second
without blinking to indicate that the appliance will return to normal operation without resetting the network
SSID.
Note: The change from the default network SSID "VORTICE_HRW" to a unique network SSID is
!
mandatory in order to prevent interference between different devices belonging to different
networks (for example, in the case of two independent flats separated by a wall, etc.).
Note: you must have a smartphone or network detection device handy to view the names of the
!
assigned networks.