HOW TO SELECT THE OUTPUTS
I:PTO anti-clockwise (standard).
A:output A (centrifugal pump).
B:output B (AIDA blower).
Figure 1 Garda Evo layout
Figure 2 Output A selected
Figure 3 Output B selected
The position of the manual lever described above is also valid with hydraulic and pneumatic rotary cylinder.
INSTALLATION
The Garda Evo group must be installed rigidly on a planar frame (sized to prevent vibrations and buckling) with a
MAX tilt of 3°. Ensure sufficient space for the circulation of cooling air and to reach the lubrication points (oil levels,
grease nipples, etc.). Leave room to manoeuvre the selection levers. Secure to the frame before the most rigid part
(Garda Evo box) and then the blower. If necessary reposition the feet with the relevant spacers.