4
Mounting
5
Electrical installation
8023329.1HTH/2023-03-02 | SICK
Subject to change without notice
Mount sensors (sender and receiver) using suitable mounting brackets (see the SICK
range of accessories). Align the sender and receiver with each other.
The minimum distance between sender and receiver is:
GSE2F(S)-xxx1xx: 24 mm
GSE2F(S)-xxx2xx: 72 mm
GSE2F(S)-xxx5xx: 238 mm
NOTE
Swap the sender and receiver arrangement at every second through-beam photoelec‐
tric sensor and ensure that there is sufficient distance between the through-beam
photoelectric sensors.
Sender (GS)
Receiver (GE)
Sender (GS)
Figure 1: Arrangement of several through-beam photoelectric sensors
Note the sensor's maximum permissible tightening torque of 0.1 Nm.
The sensors must be connected in a voltage-free state (U
tion must be observed, depending on the connection type:
Plug connection: note pin assignment: when the lid is open, the male connector
can be swiveled horizontally and vertically.
Cable: wire color
Only apply voltage/switch on the voltage supply (U
tions have been established.
Explanation of the connection diagram (Tables pin assignment):
Q = switching outputs
n. c. = not connected
DC: 10 ... 30 V DC
OPERATING INSTRUCTION
Receiver (GE)
Sender (GS)
Receiver (GE)
= 0 V). The following informa‐
V
> 0 V) once all electrical connec‐
V
O P E R A T I N G I N S T R U C T I O N | GSE2 Flat Side
en
7