5.1
Notes on UL approval
6
Commissioning
6.1
Alignment
8023329.1HTH/2023-03-02 | SICK
Subject to change without notice
Table 3: Switching output
PNP
Q
(≤ 50 mA)
Q
(≤ 50 mA)
NPN
Q
(≤ 50 mA)
Q
(≤ 50 mA)
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a)
max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b)
100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1