5.2.2 Motor unit
Malfunction
Motor is not running
Overload protection switch
always switches off (Fig. 5)
Motor runs very slowly
Motor unit becomes hot.
Motor unit makes a very
strong whistling noise
Motor vibrates
18
Cause
No power.
Cable faulty.
Switch or motor defective
Overload protection switch
off
Blade blocked (Fig. 6)
Air filter clogged (Fig. 12)
Rotor or stator faulty
Faulty overload protection
switch
Carbons consumed
Rotor or stator faulty
Air filter clogged, air can
no longer circulate (Fig. 1a,
item 28)
Clipping tension too high
Bearing faulty (penetration
of cleaning fluid)
Reduction gears and
axles without lubricant film
(Fig. 1a, Items 9+10)
Rotor runs out of round
(generated by a strong
impact)
Bearings worn out
Translation of the original instructions / Clipper
Rectification
Power supply and/or fuse
faulty.
Notify customer service
Switch on (Fig. 5)
Remove blockage.
Clean or replace air filter
Notify customer service
Notify customer service
Clean air filter in dismantled
state with brush or replace
filter
Tighten the pressure regulator
screw less strongly (Fig. 7). If
the blades no longer cut, they
must be reground or replaced
Notify customer service
Notify customer service
Notify customer service