9. Specifications
Dial
Scale range on dial
Scale
Material
Switch contacts
Switch model
Electrical connection
Electrical connection
Wire cross-section
Grounding
Quantity
Switching directions
Switch points
Electrical characteristics
WIKA operating instructions, model GDM-RC-100
End of measuring range: 1.3 bar above the first switch point
below the filling pressure
Numbering: Terminates 900 mbar above the first switch point
below the filling pressure
Extended measuring range (at least 4 bar below and 1.3 bar above
the first switch point)
Single scale (divided into sections of different colours)
Double scale (divided into sections of different colours)
Triple scale (divided into sections of different colours)
Aluminium
Potential-free change-over contacts
12-pin TTI plug-in terminal
min. 0.25 mm²
max. 2.5 mm
2
Grounding in cable socket available
1 switch contact
2 switch contacts
3 switch contacts
4 switch contacts
Up to 4 switch contacts possible as change-over contact
Falling density
Rising density
In accordance with customer specification, maximum difference
of lowest to highest contact: 4 bar
Switching voltage
≤ DC 30 V
≤ DC 50 V
≤ DC 75 V
≤ DC 125 V
≤ DC 250 V
≤ AC 125 V
≤ AC 250 V
Resistive load A
5
1)
1
0.75
0.5
0.25
5
1)
5
1)
EN
Inductive load A
3
1)
1
0.75
0.03
0.03
2
1)
2
1)
25