WIKA GDM-RC-100 Manual De Instrucciones página 27

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9. Specifications
Leak tightness
Process connection
Bellows sealing
Materials
Wetted materials
Reference chamber (pressure
element)
Process connection
Non-wetted materials
Case and cover
Cable gland M25 x 1.5
Movement
Pointer
Window
Dial
Maximum load
Minimum bursting strength
Maximum overpressure
Weight
For further specifications see WIKA data sheet SP 60.27 and the order documentation.
WIKA operating instructions, model GDM-RC-100
≤ 1 x 10
mbar x l/s
-8
≤ 1 x 10
mbar x l/s
-8
Stainless steel, filling with reference gas
G ½ B per EN 837, axial or radial, stainless steel,
spanner flats 22 mm
Other connections and connection locations on request
Aluminium die-casting, powder-coated
Plastic, sealing range 5 ... 13 mm; (optional 8 ... 17 mm)
Tightening torque: 8 Nm
Brass
Aluminium, black
Laminated safety glass
Aluminium
> 36 bar
1.43 times the measuring range
< 1,250 g
EN
27

Publicidad

Tabla de contenido
loading

Tabla de contenido