Descargar Imprimir esta página

Beninca EVA.7 Manual Del Usuario página 29

Ocultar thumbs Ver también para EVA.7:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Enables or disables motors check.
TSTm
On: Check enabled. If the check has a negative result, no manoeuvre is commanded.
Off: Check disabled.
Enables or disables the programmable code transmitters.
IMPORTANT: The transmitters with programmable code can only be used in conjunction
with the Rolling Code HCS transmitters.
Cvar
On: Radio receiver enabled only for transmitters Rolling Code (ARC or HCS, the first
transmitter sets the operating mode).
Off: Receiver enabled for transmitters Rolling Code HCS and programmable (selflearning
and dip/switch).
Selects the functioning mode of the boom light (24Vdc output on AUX2 or N.O. contact on the
output AUX 1 when configured at 2).
lBAR
On: The boom light is off when the barrier is close, it turns on when the barrier is in movement or open.
Off: The boom light flashes slowly when the barrier is close (1s pause), it flashes quickly (0,5s
pause) when the barrier is in movement or open.
The "forced opening in case of power cut-off" function is activated or deactivated (it can be
activated only with connected and operating emergency batteries).
aopf
On: Activated function. In the event of power failure, the control unit causes an opening operation.
The barrier remains open until the power supply is back.
Off: Deactivated function.
Enables or disables remote radiotransmitters learning, as indicated in the paragraph "Remote
transmitters learning".
rem
On: Remote learning enabled.
Off: Remote learning not enabled.
MENU
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the step-step function.
Press the key of the transmitter to assign to this function.
PP
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the OPEN function.
Press the key of the transmitter to assign to this function.
OPen
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the CLOSE function.
Press the key of the transmitter to assign to this function.
CLOS
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the second radio channel.
Press the key of the transmitter to assign to this function.
2Ch
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
ntx
By selecting this function the LCD screen shows the number of transmitters memorized into the receiver.
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to erase from the memory.
CLR
If the code is valid, it is erased and the message OK is displayed
If the code is not valid or not present in memory, the message Err is displayed
Completely erases memory of the receiver. Confirmation of the operation is requested. By selecting this function the receiver goes into
RTR
waiting (Push) for a new PGM pressure to confirm the operation. At end of erasing the OK message is displayed
Displays the number of complete cycles (open+close) carried out by the automation.
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG> 0012 >>> <PG>
3456: made 123.456 cycles.
This function enables to activate the maintenance request notice after a number of manoeuvres determined by the installer.
To activate and select the number of manoeuvres, proceed as follows:
Press button <PG>, the display will show OFF, which indicated that the function is disabled (default value).
With the buttons <+> and <-> select one of the numeric values proposed (from OFF to 100). The values are intended as hundreds of cycles of ma-
noeuvres (for example: the value 50 indicates 5000 manoeuvres).
Press the OK button to activate the function. The display will show the message PROG.
The maintenance request is indicated to the user by keeping the indicator lamp lit up for other 10 sec after the conclusion of the opening or closing operation.
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again resets the control unit. Note: The trans-
mitters are not erased from the receiver nor is the access password.
All the logics and all the parameters are brought back to default values, it is therefore necessary to repeat the autoset procedure.
13.3.4) RADIO (RADI)
13.3.5) CYCLES NUMBER (NMAN)
13.3.6) MAINTENANCE CYCLES (MACI)
13.3.7) RESET (RES)
FUNZIONE
(OFF)
(ON)
EN
(OFF)
(OFF)
(OFF)
29

Publicidad

loading

Este manual también es adecuado para:

Eva.8