Connection and start-up
1. Mains connection
2. Power switch on/off
ON - green (constant light)
Error – red (constant light)
Warning – yellow (constant light)
Standby – green/white (flashing at 5 sec. intervals)
SW update – green/white (flashing at 1 sec. intervals)
Adjustment of wire brake
The brake must be adjusted so tightly that
the wire roll stops before the welding wire
runs over the edge of the reel. The brake
force depends on the weight of the wire
reel and the wire feed speed.
Factory setting is: 15 kg.
Adjustment:
Dismount the control knob by placing a
thin screw driver behind the knob and
then pull it out.
Adjust the wire brake by fastening or
loosening the self-locking nut on the
axle of the wire hub.
Remount the control knob
Wire inching
Adjusting the 15 kg wire brake
From 15 kg to 5 kg: use
adaptor 45050333
12
3. Connection of shielding gas
4. Connection of welding hose
5. Connection of earth clamp or electrode holder (MMA)
6. CAN connection
7. Connection of electrode holder (MMA) or earth clamp
Software update
Insert the SD-card
Turn on the
machine
Wait until the unit
indicates that the
update is complete
Turn off the
machine and remove the SD card
The machine is now ready for use
New software will be loaded into power source and all
connected units.
The software can be downloaded from
http://migatronic.com
Licence SW
If you purchase Pulse/Duo Plus software, load the
MigaLic.dat files like the software packages.
Note! Create a backup of the files.
The MigaLic.txt file contains information about licence
number and licences saved on SD card.