Descargar Imprimir esta página

Migatronic SIGMA ONE 230 Guía De Usuario página 17

Ocultar thumbs Ver también para SIGMA ONE 230:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Technical data
Power source
Mains voltage ±15% (50-60Hz), V
Phases
Minimum generator size, kVA
1)
Minimum short-circuit power Ssc, MVA
Fuse, A
Mains current effective, A
Mains current max., A
Power 100%, kVA
Power max., kVA
Power open circuit, W
Efficiency 400V, %
Power factor
Current range, A
Duty cycle 100% 20°C (MIG), A/V
Duty cycle max. 20°C (MIG), A/%/V
Duty cycle 100% 40°C (MIG), A/V
Duty cycle 60% 40°C (MIG), A/V
Duty cycle max. 40°C (MIG), A/%/V
Open circuit voltage, V
2)
Sphere of application
Protection class
3)
Standards
Dimensions power source (HxWxL), mm
Dimensions incl. trolley (HxWxL), mm
Weight power source, kg
Weight incl. trolley, kg
Wire feed speed, m/min
Torch connection
Wire dimension, mm
Wire spool diameter, mm
Wire spool, kg
Gas pressure, max., MPA (bar)
Function
Selection of trigger mode, 2-times / 4-times
Gas pre-flow, sec.
Soft-start, m/min
Hot-start, %
Hot-start-time, sec.
Slope down time, sec.
Final current, %
Final current time, sec.
Gas post-flow, sec
Spot welding time, sec.
DUO Plus™ value
Electronic choke
Anti freeze
Arc power, %
Hotstart, %
Hot-start-time, sec.
1) This equipment complies with EN / IEC61000-3-12:2014 (/ 2011) provided that the short-circuit power Ssc of the grid at the interface point is greater than or equal to the stated
data in the abovementioned table. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that
the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to the stated data in the abovementioned table.
2) S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks.
3) The machine is designed for indoor and outdoor use according to protection class IP23S.
The machine may be stored but is not intended to be used outside during precipitation unless sheltered
Sigma One 230
400
3
16
2.6
10/16
7.2
10.5
4.9
7.2
30
88
0.94
MIG
MMA
15-230
15-230
175/23.0
175/27.6
230/40/25.5
230/40/29.0
175/23.0
175/27.6
205/24.3
205/28.2
230/40/25.5
230/40/29.0
50-60
S/CE
IP23S
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
675x250x738
814x443x1014
32.5
43.0
0.5-30.0
EURO
0.6-1.2
300
5-18
0.6 (6.0)
Process
Value range
MIG
2/4
MIG
0.0-10.0
MIG
0.5-24.0
MIG
-99-(+)99
MIG
0.0-20.0
MIG
0.0-10.0
MIG
0-100
MIG
0.0-10.0
MIG
0.0-20.0
MIG
0.0-50.0
MIG
1-50
MIG
-5.0-(+)5.0
MMA
always active
MMA
0.0-150.0
MMA
0.0-100.0
MMA
0.0-20.0
17
Sigma One 270
400
3
16
3.2
10/16
8.5
13.2
5.9
9.1
30
88
0.90
MIG
MMA
15-270
15-250
200/24.2
200/28.0
270/28/27.5
250/28/30.5
200/24.2
200/28.0
210/24.5
205/28.2
270/28/27.5
250/28/30.5
50-60
S/CE
IP23S
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
675x250x738
814x443x1014
32.5
43.0
0.5-30.0
EURO
0.6-1.2
300
5-18
0.6 (6.0)
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: SIGMA ONE 230/270
conforms to directives: 2014/35/EU
2014/30/EU
2011/65/EU
European standards
EN IEC60974-1:2018/A1:2019
EN IEC60974-5:2019
EN IEC60974-10:2014/A1:2015
Regulation:
2019/1784/EU
Issued in Fjerritslev 13.02.2023
Kristian M. Madsen
CEO

Publicidad

loading

Este manual también es adecuado para:

Sigma one 270