See built-in trim kit installation
instructions for proper location when
building in above the specified
ovens. Carefully follow both the oven
installation instructions and built-in trim
kit instructions.
The opening in the wall or cabinet must
be within the following dimensions:
A HEIGHT : 16
B WIDTH : 24
C DEPTH
: minimum 20"
Outlet should NOT be in the shaded area as indicated.
1. If the dimension of DEPTH (C) is more than 21", the outlet location may be
any area on the rear wall.
2. The floor of the opening should be constructed of plywood strong
enough to support the weight
of the microwave oven and floor
load (about 100 pounds). The
floor should be level for proper
operation of the microwave
oven. Be sure to check the local
building code as it may require
that the opening be enclosed with
sides, ceiling and rear partition.
The proper functioning of the
microwave oven does not require
the enclosure.
The built-in trim kit includes all the
necessary parts and easy-to-follow
instructions for installation as well as location of the power supply.
The ease of assembly for these kits will allow installation into an existing wall
opening in less than an hour (if power outlet is already properly located).
All it takes are four steps and a Phillips screw driver.
3
/
" - 17"
4
11
3
/
" - 24
/
"
8
16
over oven installation
29
/
"
7
16
A
B
E7
6"
"
4
4"
C

Publicidad