ENGLISH
BATTERY INSTALLATION AND BATTERY TYPE SETTING (WET OR GEL/AGM)
According to the type of batteries (WET or GEL/AGM), set the electronic board of the machine and of the battery charger, according
to the following procedure:
Machine setting (only for Adfi nity™ 17ST - 20ST)
1.
Press the switch (71) or (73) and pay attention to the following in the very fi rst seconds of machine operation:
•
If the green warning led (81a) is fl ashing, the machine is set to GEL/AGM.
•
If the red warning led (81c) is fl ashing, the machine is set to WET.
2.
If the setting is to be changed, perform the following procedure.
3.
Press the switch (71) and/or (73) to turn the machine off.
4.
Press and hold the switches (71) and (73) at the same time.
5.
Release the switches (71) and (73) at least 8 seconds after starting the machine.
6.
Within 3 seconds, press the switch (73) again for a few seconds and check that the warning led for the required setting is
fl ashing (as shown in step 1).
Machine setting (only for Adfi nity™ X20R)
1.
Turn the ignition key (80) to "I" and pay attention to the following in the very fi rst seconds of machine operation:
•
If the green led (81a) is fl ashing, the machine is set to GEL.
•
If the red led (81c) is fl ashing, the machine is set to WET.
2.
If the setting is to be changed, perform the following procedure.
3.
Turn off the machine by turning the ignition key (80) to "0".
4.
Press and hold the switches (71) and (73) at the same time, then turn the ignition key (80) to "I".
5.
Release the switches (71) and (73) at least 8 seconds after starting the machine.
6.
Within 3 seconds, press the switch (73) again for a few seconds and check that the warning light for the required setting is
fl ashing (as shown in step 1).
Battery charger setting
7.
Remove the battery charger data inspection window screws (A, Fig. 1).
8.
Remove the window (B).
9.
Turn the battery charger selector (C) to WET position for lead batteries, or to GEL/AGM position for gel batteries.
10.
Install the window (B) and tighten the screws (A).
Battery installation
11.
Open the cover (22) and check that the recovery water tank (21) is empty, otherwise empty it with the drain hose (16).
12.
Grasp the handle (41) and carefully lift the tank (40).
13.
Install the batteries.
Battery charging
14.
Charge the batteries (see the procedure in the Maintenance chapter).
12
INSTRUCTION FOR USE
B
9096912000(4)2010-11
A
C
A
Figure 1
Adfi nity™ 17ST - 20ST - X20R
S311333