Descargar Imprimir esta página

Ravelli RBC 810 Manual De Uso Y Mantenimiento página 67

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AL 06
PELLETS FINISHED
RESET THERMAL BREAKER / PELLET
AL 07
DOOR OR GATE OPEN
AL 08
DEPRESSURIZATION
FUME EXHAUST SYSTEM
AL 12
FAILURE
AL 14
SCREW PHASE
AL 15
AUGER TRIAC
NO FLOW
AL 17
(only if the RDS system is provided)
Positions of the switch
protected by a screw cap and
of the reset safety thermostat
located on the
side.
Use and maintenance manual RBC 810 - RBC 812
- The pellet tank is empty.
- The gear motor is not loading pellets
- Not enough pellets loaded
- The manual reset thermostat has tripped
connected to the hopper (RESET THERMAL
BREAKER /
Pellet door or gate is open
- Combustion in the grate is not optimal due
to the fact that the grate is clogged or the inner stove
ducts are clogged. (RESET THERMAL BREAKER)
- The flue is blocked.
- The vacuum meter is faulty.
- T he fume exhaust system has a loss of
performance due to fan obstruction or voltage drop.
- No cable connection to power the gear motor
of the auger
- An internal part of the electronic board that controls
the pellet infeed screw is faulty.
- Possible voltage drops or incorrect input voltage
stove inlet
- The flow meter does not measure inlet air flow
Page 67
- Check for the presence of pellets in the
container. Top up, if necessary.
- Empty the tank to see if there are any objects
inside that may prevent the proper operation of
the auger.
- Regulate pellets setting from "SET AIR/
PELLETS"
- If the problem persists, contact the Support
Service Support
- Reset the thermostat by pressing the button on
the back of the stove or close the doors.
- Switch off the stove, clean the brazier and the
tube bundle and adjust the combustion setting
the Pellet/Air values
- Contact the Support Service
Check the flue is free and clean
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Check the mains voltage.
- Check if the ash pan and door are
closed correctly and check if the air inlet pipe is
obstructed.
- If the problem persists, contact the Support
Service
Rev.1 14/02/18
EN

Publicidad

loading

Este manual también es adecuado para:

Rbc 812