Oil the shuttle area
NOTES:
Raise the presser foot and needle, then unplug the
machine.
Do not dismantle the machine other than as
explained in this section.
z Remove the needle and presser foot.
Remove the setscrews on the needle plate and pull
it up slightly with both hand, then remove it to the
back.
q Setscrew
w Needle plate
x Take out the bobbin. Lift up the bobbin holder and
remove it.
c Clean the hook race with a soft dry cloth.
(You may also use a vacuum cleaner.)
v Oil the point as indicated in the illustration.
Two or three drops of oil is sufficient.
z
q
x
c
v