Operation; Function Of Displays; Function Of Buttons; Temp Mode - SKF TIH 030m Instrucciones De Uso

Ocultar thumbs Ver también para TIH 030m:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
5

OPERATION

5.1

Function of displays

• The remote control display shows the selected
time or temperature for heating.
• The power LED's show the selected power
setting.
Display
Indication
t
time in minutes
°C
temperature in degrees Celcius
°F
temperature in degrees Fahrenheit
5.2

Function of buttons

Button
POWER
MODE
UP (+)
DOWN (-)
START / STOP
5.3

TEMP MODE

• If the remote control display shows 't', press MODE to select TEMP MODE. The
remote control display shows °C or °F in TEMP MODE.
• The selected temperature is shown on the remote control display. The default
temperature for bearings is 110 °C (230 °F). If a different temperature is
desired, press UP or DOWN to adjust the temperature in steps of 1°.
• It may be desirable to heat bearings to temperatures above 110 °C (230 °F) for
increased mounting time. Consult the SKF bearing specifications to determine
the maximum permitted temperature. Always ensure the bearing does not lock
due to an excessive expansion of the inner ring compared to outer ring. See
section 5.8.
• If needed press POWER to select the power level. Use the guidelines in section
5.8 to determine the correct power setting.
• Make sure the temperature probe is mounted on the bearing inner ring.
SKF TIH 030m
Function
Press to adjust the power. The selected power is indicated
with an LED.
Press to switch between TIME MODE and TEMP MODE.
Press to increase the value shown on the remote control
display.
Press to decrease the value shown on the remote control
display.
Press to start or stop the heater. The LED on the START/
STOP button is lit when the heater is heating and flashes
during temperature measurement.
11

Publicidad

Tabla de contenido
loading

Tabla de contenido