Installation Procedures; Electric Installation; Pneumatic Installation - Hofmann monty 1520-2 Manual De Operador

Desmontador de neumáticos
Tabla de contenido

Publicidad

62
monty 1520-2
iii Installation procedures

Electric installation

THE INSTALLATION SHALL BE CARRIED OUT ONLY
BY QUALIFIED PERSONNEL AND WITHIN THE SCOPE
OF THE INSTRUCTIONS PROVIDED IN THIS MANUAL.
Check on the plate of the machine that the electrical
specifications of the power source are the same as the
machine.
The machine uses
120 VAC, 60 Hz, 12 A
1 phase motor.
WORNING!
FAILURE TO PROVIDE PROPER ELECTRICAL
SUPPLYAND GROUNDING WILL CREATE A SHOCK
HAZARD TOTHE OPERATOR.
Electrical specifications are clearly marked on a label
at the end of the electric cable.
Before connecting the machine to the power source
check that the power supply has an efficient earthing
system.
Connect the electric cable of the machine with an
approved plug.
Note:
The outlet installation must be verified by
a licensed electrician before connecting
the tire changer.
Note:
The yellow/green wire in the cable is the
earth wire. Never connect the earth wire
to a live terminal.
Check that the power supply has an automatic circuit
breaker with a differential circuit rated at 30 mA.
The electric motor operates in a wide voltage range (plus
or minus 10%) and frequency range (60 Hz) and has a
class of insulation suitable for hot and moist climates.
ALL SERVICE MUST BE PERFORMED BY AN
AUTHORIZED SERVICE TECHNICIAN.

Pneumatic installation

THE AIR INSTALLATION MUST BE PERFORMED
ONLY BY LICENSED PERSONNEL.
The machine requires an air pressure of 110-170 psi (8
to 12 bar), as marked on the plate of the machine and
on a sticker attached to the cabinet next to the air inlet.
Ensure that the line pressure is within the limits required
by the machine.