Descargar Imprimir esta página

Emerson RAH ECO Manual página 21

Publicidad

Idiomas disponibles

Idiomas disponibles

7. Wall Control Installation
3-WAY INSTALLATION
(One fan controlled by two different wall controls) (See
Figures 34 and 35).
WARNING
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse or circuit breaker box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
7.7
Disconnect Electrical Power to the Branch Circuit at the
Circuit Breaker or fuse box before attempting to install the
Ceiling Fan Wall Control into the Outlet Box.
At all Wall Box locations remove Faceplates and Screws
from existing Controls. Pull Controls out from Wall Boxes
and determine which Wall Box contains the "Hot" Wire and
which Wall Box contains the "Load" Wire. Also, identify
Traveler Wires which are common to both Wall Boxes.
Disconnect Wires from existing Controls only.
Do not attempt to disconnect any Wires not already
connected to existing Controls.
Before installing the Wall Control, place the Wall Control in
"OFF" mode by pushing "ON/OFF" switch to the "OFF"
position.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
(Continued)
FAN/LIGHT
WALL
BLK
HOT
CONTROL
GROUND
BLACK
TRAVELER
WIRE
NEUTRAL
Figure 34
Install the first Wall Control in the Wall Box containing the
"Hot" Wire. Connect the Wall Control Black Wire with the
Yellow Label marked "To Power Supply" to the "Hot" Wire
in the Wall Box. Securely connect the Wires with the Wire
Connector (supplied) (Figure 34).
Connect the Wall Control Black Wire with the Blue Label
marked "To Fan" to the Traveler Wire in the Wall Box.
Securely connect the Wires with the Wire Connector
(supplied) (Figure 34).
Connect the Green Ground Wire to the Bare Copper Wire
or Green Ground Wire in the Wall Box Securely connect
Wires with Wire Connector (supplied) (Figure 34).
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
21
SECONDWALL
CONTROL
PURCHASE
SEPARATELY
GROUND
LOAD
BLACK
GROUND
WARNING
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF915

Publicidad

loading