Descargar Imprimir esta página

Ryobi RYi900LP Manual Del Operador página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

GENERATOR CAPACITY
Make sure the generator can supply enough continuous (run-
ning) and surge (starting) watts for the items you will power
at the same time. Follow these simple steps.
1. Select the items you will power at the same time.
2. Total the continuous (running) watts of these items. This
is the amount of power the generator must produce to
keep the items running. See the wattage reference chart
at right.
3. Estimate how many surge (starting) watts you will need.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Because not all motors start
at the same time, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
Tool or Appliance
Inflator Pump
Laptop
46 in. Flat Panel
Television
Light (75 Watts)
Running Watts
Highest Starting Watts
Total Starting Watts Needed
POWER MANAGEMENT
To prolong the life of the generator and attached devices,
it is important to take care when adding electrical loads to
the generator. There should be nothing connected to the
generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the engine
as described later in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
ELECTRICAL
Running
Starting
Watts*
Watts*
50
150
250
0
190
0
75
0
565 Total
150 Highest
Starting Watts
Total Running Watts
+ 150
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity
as previously described.
NOTICE:
Do not overload the generator's capacity. Exceeding the
generator's wattage/amperage capacity may damage
the generator and/or electrical devices connected to it.
Application/Equipment
Emergency / Home Standby
Lights (qty. 4 x 75 W)
46 in. Flat Panel Television
Satelite Receiver
Portable Fan
Laptop
Slow Cooker
Radio
565
*Wattages listed are approximate. Check tool or appliance for actual wattage.
715
11 — English
Estimated
Estimated
Running
Starting
Watts*
Watts*
300
0
190
0
250
0
200
0
250
0
270
0
200
0

Publicidad

loading

Este manual también es adecuado para:

Ryi911lp