Descargar Imprimir esta página

Siemens KG39FPI45 Instrucciones De Uso página 28

Publicidad

Idiomas disponibles

Idiomas disponibles

en
Fault
The side panels of the
appliance are warm.
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
Automatic super freezing
does not switch on.
The following settings are
switched off:
Audible signals
Interior lighting
Messages on the display
panel
Automatic super freezing
The background illumination
of the display panel is
reduced.
Buttons are locked.
Appliance is not cooling,
temperature display and light
are lit.
28
Possible cause
Pipes run into the side panels
which heat during the
cooling process.
The evaporator (refrigeration
generator) in the
NoFrost system is covered
in thick ice and can no
longer be defrosted fully
automatically.
Sabbath mode is switched
on.
Showroom mode is switched
on.
Remedial action
That is normal behaviour for the appliance and
not a fault.
Furniture touching the appliance will not be
damaged by the heat.
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance.
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
The appliance decides independently whether
automatic Super freezing is required and
automatically switches it on or off.
Press super button for 15 seconds.
Press and hold °C button and @ setting button
for 5 seconds until an acknowledgement
signal sounds. Another acknowledgement
signal sounds when the buttons are released.
After a short time check whether your
appliance is cooling.