Propane Tank Safety Instructions
CAUTION: Only qualified persons should fill your LP-Gas containers.
ATTENTION: Les contenants de gaz de pétrole liquéfié doivent être remplis uniquement par des personnes qual-
ifiées.
1.
Never allow your LP-gas container to be filled above the maximum safe level as indicated by a scale or the fixed
liquid level gauge (outage). Do not use the visible gauge for filling.
2.
Do not use a wrench or pliers to close the service valve or fixed liquid level gauge. These valves are designed to be
closed leak-tight by hand or screwdriver as appropriate. If wrenches are necessary to stop a leak, the valve needs
repair or replacement.
3.
When tightening the POL Nut (left hand thread) on the service valve, draw it up snug with a proper wrench. This is a
machined male brass fitting which seats securely against a female seat in the POL valve – no pipe dope is neces-
sary. Acme/Type 1 valves have right handed threads which are secure when hand tight, and on the Quick Discon-
nect/Type 2 Valves, the male connection is inserted into the female connection on the cylinder valve. (No wrenches
required for both the Acme and the Quick Disconnect.)
4.
When using container, slowly open service valve all the way. Listen to the regulator. A continuous hiss may indicate
a leak or an open valve on an appliance.
5.
Check all tank and the line connections periodically to be sure they are tight. When testing for leaks, use approved
leak detector solution – not matches.
6.
Make certain your container is properly fastened in place.
7.
Turn container with open part of container guard towards frame. This protects valves and regulator against flying
rocks and mud. Transport container in the proper position in which it is used, with the valves closed and POL Plugs
inserted for POL Valves or Dust Caps for Acme Valves. Secure the tank against falling or rolling.
8.
Check for leaks after connecting. Apply approved leak detector solution to connection, turn off all burners and pilots,
and open service valve. Leaks will be detected by the growth of the bubbles. If bubbles grow, tighten or repair the
connection as needed. Repeat leak test until problem is corrected.
9.
LP-gas is normally non-corrosive – you need not worry about the inside of your container. However, the outside
should be kept free from rust by a periodic coat of paint in a light reflective color. It is very important to inspect and
maintain the bottom and foot ring on the container.
10. Do not store LP-gas containers indoors or in enclosed areas. Do not expose LP-gas container to heat. Always store
with service valve closed and plugged as required.
11. Do not attempt to repair any containers, container valves, regulator or appliances by yourself. Use only trained
certified LP-gas service personnel to perform repairs.
CAUTION: Propane tanks, gas bottles will not be picked up by local garbage collectors. Improper propane
tank disposal might be illegal in some areas.
ATTENTION: Les bouteilles de propane, les bouteilles de gaz ne seront pas acceptées par les éboueurs
locaux.
Propane tank disposal is a safety issue that is easily handled by a propane company.
VHP 2-1500 / 3-2000 Operator's Manual 8.913-949.0 - AU
Example Of Down
Draft Diverter For Gas Fired Machines
Safety
9