DOOR PANEL PROGRAMMING
Coming from previous page
door open time
:03
modify value
:03
1
0
door open time
:10
version 5.00
End of the configuration menu. Use "UP" arrow key to move to the previous options.
Press CANCEL to exit from the configuration menu and return to the main menu.
If CANCEL is pressed twice the panel will exit from the programming menu.
C
onfiguration menu.
Allows to set the lock release activation time.
Modify this value when the panel is placed
far from the door. The value is shown in
seconds and the factory default value is
3 seconds.
O.K.
To change this value press OK: the display
will show the message
modify value
Key in the new activation time and confirm
by pressing OK.
If CANCEL is pressed the former value
will be restored.
The lock release will not be activated if a null
O.K.
value is introduced. To avoid lock release
overheating do not introduce a high value.
Displays the door panel software version.
Continue
110
111
Coming from previous page
access control
*
access control
.
1
st
modify value
4
1
st
2
nd
3
rd
DOOR PANEL PROGRAMMING
To enter into access control menu, follow
the steps described on page 106
O.K.
and press OK when the display shows the
message
access cONtrOl
Allows to enable or disable the access control
feature (lock release activation by entering
yes
a PIN code).
Press OK to change this value.
The system has three different codes to activate
access code
the lock release.
:2222
To change the first code press OK: the display
will show the message
Key in the new code and confirm by pressing
O.K.
OK.
If CANCEL is pressed the former value
will be restored.
:2222
Always use a four digits code.
0
1
3
O.K.
access code
:4013
To change the second code proceed as
access code
described on the previous menu.
:3333
To change the third code proceed as
access code
described on the previous menu.
:4444
This code allows the lock release activation
during a programmable time period,
as described on the next menu.
A
ccess control menu.
.
.
modify value
Continue