To the monitors
FA-Plus/C or FA-Plus
PRI
SEC
~
~
+ +
-
-
Main
D4L-PLUS
S1
JP1
+
E
S
S2
v
ideo installation with general entrance door panel
IMPORTANT NOTES:
To wire and configure the system properly, use this instruction manual and the ones enclosed
in the internal building door panels.
The installation diagram shows the connection of a video system with two general entrance
door panels and up to 128 internal building door panels.
In case of more than two general entrance door panels, wire them as the second is connected.
In video systems, use a D4L-Plus distributor at each door panel input except on the last one.
Remove the end of line jumper of all the distributors except in the last one.
In case of audio systems only, do not use coaxial cable neither distributors. On the buildings
backbones coaxial cable must be replace by a negative wire.
Refer to the previous installation diagrams for monitors or telephones connection.
136
BUILDING 127
JP
1
2
3
4
SW1
CN1
CV-
CV+
-
+
D
A
A
V
V
V
V
Malla
out
in
in-
in+
out+
out-
for residential complexes.
137
To the monitors
FA-Plus/C or FA-Plus
PRI
SEC
~
~
+ +
-
-
Main
v
SECTIONS CHART
Terminal
+, – , CV+, CV –
A , A , A, D
in
out
V , V
, V , V
in+
out+
in
out
For longer distances than the specified contact with your distributor.
INSTALLATION DIAGRAMS
BUILDING 128
JP
1
2
3
4
SW1
CN1
CV-
CV+
-
+
D
A
A
V
V
V
V
Malla
out
in
in-
in+
out+
out-
ideo installation with general entrance door panel
for residential complexes.
Distance
100m.
300m.
1,50mm²
2,50mm²
0,25mm²
0,25mm²
RG-59
RG-59