Descargar Imprimir esta página

golmar Stadio Plus Manual De Instalación página 72

Portero electrónico y videoportero instalación digital con placa codificada
Ocultar thumbs Ver también para Stadio Plus:

Publicidad

Idiomas disponibles

Idiomas disponibles

OPTIONAL CONNECTIONS
The use of a SAR-90 relay will be required to activate a second camera and an internal
modification on the monitor shall be done, as it's described on page 119.
This facility disables the intercom function. If both functions are required, use A1 terminal to
activate the second camera.
To activate this function, press
monitor push button at any moment with no dependence of
the handset position.
If this device is shared for all the monitors, link their 2C terminal and use just one relay unit.
In case that each monitor has its own camera use a SAR-90 relay unit for each monitor
and don't link the 2C monitor terminals.
This push button can be used to activate other auxiliary devices, as the A1 terminal is used.
Usual applications are the surveillance of the elevator entrance, reception hall, ...
SAR-90
+
SA
T
R
M
T
R
M
D
oor bell push button connection.
The Platea Plus monitor and the T-940 Plus telephone can be used to receive the calls made
from the apartment door, saving the use of a bell. Wire the push button of the apartment
door to the 'HZ ' and ' ' monitor or telephone terminals.
The reproduced acoustic tones are different depending on their provenance, that allows the
user to distinguish where the call is made from. If during a conversation a call is made from
the apartment door, acoustic tones will be reproduced on the hanset to advise that someone
is calling.
A
ctivation of a second camera.
CN4
_
+
V
V
Malla
A
D
2C
in
out
-
HZ-
140
141
An easy way to check that the system is working properly is to disconnect the wiring from the door
panel and to check the monitor directly connected to the door panel terminal connector.
No shortcircuit will damage the connected units, with the exception of a shortcircuit between
CTO and ' ' monitor or distributor terminals.
Nothing operates.
Check the output power supply voltage between ' ' and '+' terminals: it should have 17,5 to
18,5Vd.c. If not, disconnect the power supply from the installation and measure again. If
it's correct now, it means there is a short circuit in the installation: disconnect the power
supply from mains and check the installation.
Check that 'D' terminal is not shortcircuited with ' ' or '+' terminals.
Check that 'D' terminal hasn't been changed by 'A' terminal somewhere in the installation.
Inappropriate audio level.
Adjust the level volumes as shown on page 105. In case of feedback, reduce the audio levels
until feedback fade out. If feedback don't dissapears refer to the following hint.
Continuous audio feedback.
Check that 'A' terminal is not shortcircuited with other terminals.
Door open function no operates.
Remember that this function is only available during call and communication progresses.
Disconnect the lock release from door panel terminal connector and short-circuit terminals ' '
and 'CV ': at that moment the output voltage between terminals 'CV+' y 'CV ' should be
12Vd.c. If it's so check the lock release and its wiring.
The system cannot be programmed.
If you are programming push buttons door panels, check that the switch number 2 of the
configuration dip switch is set to ON, and that the programming steps are correctly
followed. In case of coded door panels, check that the panel is into program mode (see
pages 123 and 126).
Check that 'D' terminal is not shortcircuited with other terminals.
Check that the door panels jumper corresponding to the communications resistor are properly
placed, as shown on the installation diagrams.
Some units don't receive calls.
Remember that each apartment must have a master unit only. Check that the units are
switched on and correctly programmed.
TROUBLESHOOTING HINTS

Publicidad

loading

Este manual también es adecuado para:

T3403ml